Working sites you can open. Owners publish them. A link that keeps updating proves more than a screenshot.
40 of 40 public devices
EarthPulse collects live weather, air quality, UV index, and currency exchange rate data from multiple cities worldwide using free public APIs.
Long cycle test rig. Left it running over a weekend once and found out on Monday that it had stopped on the Friday night.
Small server room on a precision unit. Honestly this is here so I know how much headroom is left in the hottest week of the year.
Vapour around the depot, with extraction status right next to it so I can tell which one is the problem.
Frost watch through the season. One night is all it takes.
Monitoring at the board. We had equipment failing and nobody could say why. Turned out to be sags, not the equipment.
22 kW drive on line two. The vibration trend is the entire reason it is monitored.
Feed pump on the boiler. It threw a bearing in March and took the boiler down with it. Now it is watched.
Thirty seven degrees, tight tolerance. A short excursion overnight invalidates a week of work and you would never know.
Clean baseline on campus. We hold the roadside numbers up against this one.
Cycle counts, utilisation, and every short stop. Quoted capacity and actual capacity have never been the same number.
Dewatering the pit. If this stops, work stops, so it gets watched properly rather than checked on.
One multi-deck on the chilled aisle. I am trying to work out whether the shrinkage is the case or the staff.
96 kWp across the warehouse roof. I check yield against irradiance most mornings. When it drifts below where it should be, the panels want washing.
District meter. Night flow is the number that matters. Whatever is still moving at three in the morning is leaking.
A zone on ageing pipework, metered on its inlet against the volume billed within it. Physical leakage runs at the same rate all night, so where the loss is water in the ground rather than water unbilled, the minimum night flow says so plainly.
Carbon monoxide in the underground car park. The fans used to run on a timer whether anyone needed them or not.
A commercial zone where the pipework is sound and the loss is still large. Water that reaches a customer and is never billed follows the demand curve instead of running all night, which is why two zones can lose the same share and need entirely different work.
Main cold store, product for export. Since we started logging door time the arguments stopped.
Incoming supply for the whole building. Tenants ask what happened. Now I can tell them.
LPG in a hotel kitchen. Reads zero nearly always. That suits me fine.
Sat beside a busy road. Mornings are worse than I expected. Still air holds everything in until the sun gets up.
Compressed air costs us more than lighting and heating together. This is where I prove it to people.
One residential zone of a distribution network, metered on its single inlet, with the volume billed inside the zone alongside it. The gap between the two is non-revenue water, and splitting a network into zones is what turns one town-wide loss figure into somewhere to send a crew.